• Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd Application
  • Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd Application

Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd Application

Certification: EMC, ISO9001:2000, RoHS, CE
Rated Current: 1-4A
Voltage: 3V
Material: Plastic
Power: Electric
Valve Body Type: Diaphragm
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • typical application
  • Detailed Photos
  • Product Parameters
  • Main features
  • Installation Instructions
Overview

Basic Info.

Model NO.
7121-31-ELA
Function
Electronic Type
Diaphragm Material
EPDM/FKM/HNBR
Performance
Wearable
Valve Body
Materials Can Be Replaced Based on Medium
Motor
DC Motor or BLDC Motor, Optional
Transport Package
Blister+Foam
Specification
42.8*34.2*22.5
Trademark
Keyto
Origin
China
HS Code
84135031
Production Capacity
500, 000PCS Per Year

Product Description

Product Description

7121 series diaphragm liquid pump is independently developed by Keyto. The main function is through the motor diaphragm reciprocating movement to achieve gas suction and discharge.
The principal of diaphragm pump is the elastic diaphragm reciprocating by centrifugal wheel rotating, to change the volume of chamber. And we designed single direction poppets at input and output port, to achieve medium aspiration and dispensing.

typical application

This series is widely used in medical equipment, environmental protection equipment, meters, chemical machinery, household appliances, laboratory instruments and other high-end applications.
Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd Application

Detailed Photos

Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd ApplicationSingle Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd Application

Product Parameters
Non-corrosion resistant diaphragm pump parameters table
1.Brush motor diaphragm pump
Model 7121-31-ELA 7121-32-ELA 7121-61-ELA 7121-62-ELA
Rated power consumption/ W <7W <7W <7W <7W
Rated voltage/ DC 12V 24V 12V 24V
Flow under Atmospheric pressure ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height (liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Safety protection current / / / /
Rated current(A) ≤0.36 ≤0.16 ≤0.36 ≤0.16
Connection port 4mm inner diameter silicone tube
Lifetime 3000 hrs
Medium Water, weak acid and base, etc.
Body material PP(Materials can be replaced based on medium)
Diaphragm material EPDM(Materials can be replaced based on medium)
Note: The suction negative pressure standard: the value is larger than standard value. (e.g.: -80Kpa)        
2.Brushless motor diaphragm pump
Model 7121-31-ELN 7121-32-ELN 7121-61-ELN 7121-62-ELN
Rated power consumption/ W <7W <7W <7W <7W
Rated voltage/ DC 12V 24V 12V 24V
Flow under Atmospheric pressure ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height(liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Rated current/ A 0.5 0.25 0.5 0.25
Safety protection current/A 2.0 1.2 2.0 1.2
Model 7121-31-ELM 7121-32-ELM 7121-61-ELM 7121-62-ELM
Rated power consumption/ W <7W <7W <7W <7W
Rated voltage/ DC 12V 24V 12V 24V
Liquid flow under Atmospheric pressure (full speed) ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height(liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Rated current/ A 0.5 0.25 0.5 0.25
Safety protection current/ A 2.0 1.2 2.0 1.2
Connection port 4mm inner diameter silicone tube
Lifetime >10000hrs
Medium Water, weak acid and base, etc.
Body material PP(Materials can be replaced based on medium)
Diaphragm material EPDM(Materials can be replaced based on medium)
Note: The suction negative pressure standard: the value is larger than standard value. (e.g.: -80Kpa)       
Corrosion resistant diaphragm pump parameters table
1 Brush series diaphragm pump
Model 7121-31-TLA 7121-32-TLA 7121-61-TLA 7121-62-TLA
Rated Power Consumption/W <7W <7W <7W <7W
Rated voltage/DC 12V 24V 12V 24V
Flow under Atmospheric pressure ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height (liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Safety protection current /A / / / /
Rated current /A ≤0.36 ≤0.16 ≤0.36 ≤0.16
Connection port 4mm inner diameter silicone tube
Lifetime >1000hrs
Medium Water, acid and base, etc.
Body material PP,POM(Materials can be replaced based on medium)
Diaphragm material fluororubber(Materials can be replaced based on medium)
Note: The suction negative pressure standard: the value is larger than standard value. (e.g.: -80Kpa).
If you have special reagent tolerance requirements, please consult our technical staff.     
 
Model 7121-31-PLA 7121-32-PLA 7121-61-PLA 7121-62-PLA
Rated Power Consumption/W <7W <7W <7W <7W
Rated voltage/DC 12V 24V 12V 24V
Flow under Atmospheric pressure ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height (liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Safety protection current /A / / / /
Rated current /A ≤0.4 ≤0.2 ≤0.4 ≤0.2
Connection port 4mm inner diameter silicone tube
Lifetime >1000hrs
Medium Water, acid and base, etc.
Body material PTFE,ETP(Materials can be replaced based on medium)
Diaphragm material fluororubber(Materials can be replaced based on medium)
Note: The suction negative pressure standard: the value is larger than standard value. (e.g.: -80Kpa).
If you have special reagent tolerance requirements, please consult our technical staff.     

2 Brushless series diaphragm pump
Model 7121-31-TLN 7121-32-TLN 7121-61-TLN 7121-62-TLN
Rated Power Consumption/ W <7W <7W <7W <7W
Rated voltage/ DC 12V 24V 12V 24V
Liquid flow under Atmospheric pressure ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height (liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Rated current /A 0.5 0.25 0.5 0.25
Safety protection current /A 2.0 1.2 2.0 1.2
Model 7121-31-TLM 7121-32-TLM 7121-61-TLM 7121-62-TLM
Rated Power Consumption/W <7W <7W <7W <7W
Rated voltage/DC 12V 24V 12V 24V
Liquid flow under Atmospheric pressure (full speed) ≥0.30L/min ≥0.30L/min ≥0.60L/min ≥0.60L/min
Max aspirating height ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa ≥0.2Mpa
Max drainage height (liquid) ≤-80Kpa ≤-80Kpa ≤-80Kpa ≤-80Kpa
Operating temperature 0-40ºC 0-40ºC 0-40ºC 0-40ºC
Rated current /A 0.5 0.25 0.5 0.25
Safety protection current /A 2.0 1.2 2.0 1.2
Connection port 4mm inner diameter silicone tube
Lifetime >5000hrs
Medium Water, acid and base,etc.
Body material PP,POM(Materials can be replaced based on medium)
Diaphragm material fluororubber(Materials can be replaced based on medium)
Note: The suction negative pressure standard: the value is larger than standard value. (e.g.: -80Kpa).
If you have special reagent tolerance requirements, please consult our technical staff.        

Note: 
1.
All flow and pressure are tested under standard atmospheric pressure;
2.
If you have special reagent tolerance requirements or characteristic parameters, please consult our technicians;
Main features

Characteristics:
1)Offer pure liquid transport and gas aspirate environment;
2)Oilless, maintenance free, long lifetime;
3)Small vibration, low noise;
4)Good sealing, corrosion protection and corrosion resistance;
5)Easy to assemble.

Installation Instructions

Brush series 30 diaphragm pump

Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd ApplicationBrushless series 30 diaphragm pump
Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd ApplicationBrush series 60 diaphragm pump
Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd ApplicationBrushless series 60 diaphragm pump
Single Head Diaphragm Liquid Pump for Laboratory/Medical/Environmental Instruments/Ivd Application

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
449
Year of Establishment
2010-11-16