Media: Water, Air, Strong Acid and Base
Temperature: 5-40 Degree
Actuator: Electric
Connection Form: Flange
Type: Direct Acting
Material: PMMA, POM, PTFE, PVDF Body,EPDM/FKM/Ffkm Menbrane
Samples:
US$ 180/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Ms. Keyto Marketing Team
Marketing Manager
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
1351-22-TFU/5N
Pressure
-70 Kpa ~ 0.2 MPa
Valve Structure
Pilot Membrane Structure
Power Supply
DC Solenoid Valve
Usage
Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Medical/Laboratory/Environmental Device Usage
Manifold
Machining Component
Transport Package
Bulk Package
Specification
valve bank
Trademark
Keyto
Origin
China
HS Code
8481804090
Production Capacity
200, 000 PCS/Year

Product Description

1. Production Overview
The 13X1-2 series is a family of diaphragm solenoid valve with manifold, and its mainly
function is to switch on and switch off the liquid. These series have multiple option types, which
can be customized with different number of ports and they are suitable for different reagents in
different condition. It's a high precision, low cost and maintenance-free solenoid valve and its life
cycle is more than 2 million.
Manifold Valve for Medical/Laboratory/Environmental Instruments Application
1.1.Characteristics Of 13X1-2 Series
Customized: solenoid valve manifold can be customized with different number of ports,
arrangement method and mounting ports according to customers' requirement.
Small dead volume: no dead volume inside the solenoid valve body
Multiples option for wetted material:
1. Body material : PTFE, POM,PVDF,PMMA
2. Seal material : EPDM, FKM,FFKM
Long lifetime, good performance.
 
Response Time (T)
  Input air/water at 0.25MPa and maximum working pressure drop from inlet port, input rated
control electrical signal to make the tested solenoid valve open and close, then we'll get the
change of outlet pressure which we can measure from pressure sensor. At the same time, we'll
get the lapse of time which starts from power on/off to rise to 90% of max pressure (normally 
closed valve) and drop to 10% of max pressure (normally open valve) by quick response time
measure devise. Repeatedly test several times and take the average valve as the power on
response time and the power off response time.
  As engineering experience, it is the design critical value that response time above 50ms. The
aspiration of valve may not stable. Therefore, the response time is not beyond 50ms within
nominal lifetime.
  In addition, there is a response time at current method in this industry. The change of circuit
leads to current change, according to the action of solenoid valve. The response time T1, T2 at
current method is normally less than the response time(T) which measured by air flow method.
 
Seal Capability
Pressure strengthen (outside leakage)
Solenoid valve powers on, the outlet is close, and the inlet water under condition of 5 ºC ~40 ºC
and nominal pressure is 1.5 times. Then ensure all connector won't leak within 1min.
Sealing (inside leakage)
For two normally closed branches, give one port pressures; put the other port into water.
Under the nominal pressure, there is no bubble come out in 1min

Product Features: 
Configuration with one common inlet and multiple outlets; 
Easy to install, small size and save space, each valve can be control seperately, strong acid and base resistance.
Ideal for application in limited space.

Advantage of integrated solution: 
Customized as customer requirement; 
Less assembly time, lower assembly defects; 
Optimize details, improve customers' competitiveness; 
System package, maintenance free.

Specification:  
Model 13X1-2 Direct-acting Solenoid Valve Module
Body material PMMA, POM, PTFE, PVDF
Seal material  FKM,FFKM, EPDM
Structure Direct-acting diaphragm
Number of port 2 common port + 1 optional port + 5 optional branch
Orifice diameter 2 mm
Coefficient Of Variation
(CV)
0.03
Operating
Temperature
5 ºC ~40 ºC
Mediums
Water, air, weak acid and base corrosive
(Material will be decided based on medium. If strong acid and base
corrosive request, please contact Keyto.)
Flow 5.1 g/s (water, 25ºC, 50KPa)
Power consumption 4.2 W (single valve) 
Operating pressure -70 KPa ~ 0.2 MPa
Voltage Tolerate
-10% ~ +10%
Response
<30ms

Product photo
Manifold Valve for Medical/Laboratory/Environmental Instruments Application Manifold Valve for Medical/Laboratory/Environmental Instruments Application Manifold Valve for Medical/Laboratory/Environmental Instruments Application Manifold Valve for Medical/Laboratory/Environmental Instruments Application Manifold Valve for Medical/Laboratory/Environmental Instruments Application


 