• Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
  • Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
  • Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
  • Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
  • Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
  • Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application

Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application

Media: Water, Air and Some of Organic Solvents
Temperature: Ordinary Temperature
Actuator: Electric
Connection Form: Tubular
Type: Direct Acting
Material: PPS/POM/PVDF/PTFE Body, EPDM/FKM/Ffkm Membrane
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (25)

Basic Info.

Model NO.
1022-22-EPN/5N
Pressure
-70 Kpa ~ 0.3 MPa
Valve Structure
Direct Action Diaphragm Structure
Power Supply
DC Solenoid Valve
Usage
Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Medical/Laboratory/Environmental Device Usage
Size
20.5 * 23.5 * 50.7 mm
Voltage
12V
Power
3.5W
Transport Package
Bulk Package
Specification
CE, RoHS
Trademark
Keyto
Origin
China
HS Code
8481804090
Production Capacity
1000, 000 PCS/Year

Product Description

1. Production Overview
The solenoid valve of 1022-2 series is a family of diaphragm valve with 2mm orifice
diameter, controlling the switch of fluid flow path. This series solenoid valve is a high
performance, low cost and maintenance free diaphragm valve with multiple model options,
which are suitable for different reagents under different working condition.The life cycle of
valves can be operated more than 2 million.
Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
1.1.Characteristics Of 1022-2 Series
Orifice diameter: 2mm; small resistance along the way
Large flow: CV≥0.04; flow≥6.8mL/s(differential pressure 50KPa, 25ºC, pure water)
Small dead volume: zero dead volume inside the solenoid valve
Multiple option for wetted material:
1. Body material: PPS, POM,PTFE
2. Seal material: EPDM, FKM
Long lifetime, high performance.
Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
1.2.Words Definition
The coefficient of variation (CV)
It is remarked as CV, but in China we mark it as KV. They are both non-dimensional
parameters and replacement. CV means the liquid flow capability of elements. In actual
design and use.
When it replaced as common physical dimension parameter in China, then:
CV=0.04, means under the condition of 25ºC, 50KPa, the flow of component is
6.8ml/s.
Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments Application
Response Time (T)
Input air/water at 0.25MPa and maximum working pressure drop from inlet port, input
rated control electrical signal to make the tested solenoid valve open and close, then we'll
get the change of outlet pressure which we can measure from pressure sensor. At the
same time, we'll get the lapse of time which starts from power on/off to rise to 90% of max
pressure (normally closed valve) and drop to 10% of max pressure (normally open valve)
by quick response time measure devise. Repeatedly test several times and take the
average valve as the power on response time and the power off response time.
As engineering experience, it is the design critical value that response time above
50ms. The aspiration of valve may not stable.Therefore, the response time is not beyond
50ms within nominal lifetime.
In addition, there is a response time at current method in this industry. The change of
circuit leads to current change, according to the action of solenoid valve. The response
time T1, T2 at current method is normally less than the response time(T) which measured
by air flow method.
 
Seal Capability
Pressure strengthen (outside leakage)
Solenoid valve powers on, the outlet is close, and the inlet water under condition of
5ºC~40ºC and nominal pressure is 1.5 times. Then ensure all connector won't leak within
1min.
Sealing (inside leakage)
For two normally closed branches, give one port pressures; put the other port into
water. Under the nominal pressure, there is no bubble come out in 1min.
1022-2 Series Specification:
Model 1022-22-EPN/5N Barbed Solenoid Valve
Body material PPS, POM, PVDF, PTFE
Diaphragm material  EPDM, FKM, FFKM
Outline Dimension 20.5 * 23.5 * 50.7 mm 
Structure Direct-acting diaphragm
No. of ports 2
Orifice diameter 2 mm
Flow 6.8 g/s (25ºC, 50kPa, water)
Power consumption 3.5 W
Operating pressure -70 kPa ~ 0.3 Mpa

Attention: 
1. The pressure should be put on the inlet, no matter what kind of pressure.
2. To prevent the nozzle from broken, body ported valve should be inserted or pulled out the hose along with the direction of nozzle.


Product Photo
Direct Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments ApplicationDirect Acting Diaphragm Valve for Ivd/Laboratory Instruments Application




 

Send your message to this supplier