Media: Air, Inks, Weak Acid & Base, Some Organic Solvents
Temperature: Ordinary Temperature
Actuator: Electric
Connection Form: Tubular
Type: Direct Acting
Material: PPS/POM/PVDF/PTFE Body, EPDM/FKM/Ffkm Membrane
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (25)

Basic Info.

Model NO.
1032-22-EPN/5N
Pressure
-70 Kpa ~ 0.2 MPa
Valve Structure
Direct Action Diaphragm Structure
Power Supply
DC Solenoid Valve
Usage
Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Medical Device Usage
Size
20.5 * 23.5 * 51.2 mm
Transport Package
Bulk Package
Specification
CE, RoHS
Trademark
Keyto
Origin
China
HS Code
8481804090
Production Capacity
200, 000 PCS/Year

Product Description

1. Production Overview
The solenoid valve of 1032-2 series is a family of diaphragm valve with 2.5mm orifice
diameter, controlling the switch of fluid flow path. This series solenoid valve is a high
performance, low cost and maintenance free diaphragm valve with multiple model options,
which are suitable for different reagents under different working condition.The life cycle of
valves can be operated more than 2 million.
1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application
1.1. Characteristics Of 1032-2 Series
Orifice diameter: 2.5mm; small resistance along the way
Large flow: CV≥0.05;flow≥8.5mL/s(differential pressure 50KPa, 25ºC, pure water)
Small dead volume: zero dead volume inside the solenoid valve
Multiple option for wetted material:
1. Body material: PPS,POM,PVDF,PTFE etc.
2. Seal material: EPDM, FKM FFKM etc.
Long lifetime, high performance.
1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application
Response Time (T)
  Input air/water at 0.25MPa and maximum working pressure drop from inlet port, input
rated control electrical signal to make the tested solenoid valve open and close, then we'll
get the change of outlet pressure which we can measure from pressure sensor. At the
same time, we'll get the lapse of time which starts from power on/off to rise to 90% of max
pressure (normally closed valve) and drop to 10% of max pressure (normally open valve)
by quick response time measure devise. Repeatedly test several times and take the
average valve as the power on response time and the power off response time.
  As engineering experience, it is the design critical value that response time above
50ms. The aspiration of valve may not stable.Therefore, the response time is not beyond
50ms within nominal lifetime.
  
In addition, there is a response time at current method in this industry. The change of
circuit leads to current change, according to the action of solenoid valve. The response
time T1, T2 at current method is normally less than the response time(T) which measured
by air flow method.
1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application
Seal Capability
Pressure strengthen (outside leakage)
Solenoid valve powers on, the outlet is close, and the inlet water under condition of
5ºC~40ºCand nominal pressure is 1.5 times. Then ensure all connector won't leak within
1min.
Sealing (inside leakage)
For two normally closed branches, give one port pressures; put the other port into
water. Under the nominal pressure, there is no bubble come out in 1min.
1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application
Specification
Structure  Direct acting poppet type
Type 2/3-way N.C
No.Of Ports  2
Orifice Diameter 
2.5mm
Coefficient Of Variation (CV)   0.05
Mediums
Water, air, weak acid and base (The material will be decided based
on mediums. If strong acid and base corrosive request, please
contact keyto.)
Operating Temperature
0ºC(no freezing)~60ºC
Operating Pressure(in - out) 
-70Kpa~0.2Mpa
Leakage Rate  0
Response Time
<30ms
Dead Volume  0
Voltage Tolerance DC12V,24V
Fluctuation Of Voltage From-10% to+10%
Power Consumption  3.5W
Type of coil insulation B
Recommended
Connector
Inner diameter of the hose should be 2.5mm ~3.5mm (shore
hardness around:55~ 75). It need truss a wire to increase the
sealing reliability cause the rubber tube is too soft.
Wight  80g

Photo
1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application1032 Diaphragm Valve for Medical/Laboratory/Environmental Instruments Application




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
449
Year of Establishment
2010-11-16