• Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application
  • Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application
  • Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application
  • Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application
  • Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application
  • Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application

Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application

Standard or Nonstandard: Standard
Feature: Corrosion-Resistant
Application: Ivd/PCR/Laboratory Instruments
Surface Treatment: Sand Blasting
Material: Special Oxidation Treatment
Max Displacement: 1000UL
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (25)

Basic Info.

Model NO.
SP18-2A-010
Tip Volume
10UL, 50UL, 200UL, 1000UL
Liquid Level Detection
Plld
Communication Protocol
RS232, RS485, Can
Power Consumption
24VDC
Lifetime
1 Millions
Driver Design
BLDC Stepper Motor
Center Spacing
18mm
Functional
Liquid Level Detection,Clots Detection and So on
Liquid Speed
10ms
Weight
400g
Dimension
250.3*74.3*17mm
Additional Option
Z-Axis and Movement Mechanism
Operating Temperature
-15°+35°
Transport Package
Carton + Bubble Bun
Specification
CE, RoHS
Trademark
Keyto
Origin
China
HS Code
8479909090
Production Capacity
500, 000 PCS/Year

Product Description

  1.  Product Overview
  2. The Superb Air Displacement Pipettor (SADP) is a Keyto module based on pneumatic aspirate and dispense technology for pipetting with disposable tips. With disposable tips of different specifications, automatic aspirate and dispense within the range of 5-1000ul can be realized.The Keyto SADP offers a swift and reliable mechanical adapter module, as well as common communication interface, which are suitable for integration in pipetting platforms and pipetting units of test equipment that are sensitive to cross-contamination, providing a reliable and excellent-performance pipetting module for all types of equipment.
 
  1. SADP18 Series Pipettes Main Features
  2. This pipette has a unique mechanical structure that allows multiple air displacement pipettors to be used in conjunction with each other, and the loading of disposable tips allows 18 mm disposable tips-to-disposable tips center spacing, which greatly increases pipetting velocity.
  3. The pipette is equipped with a excellent-performance drive control unit and provides CAN, RS232 and RS485 communication interface and the corresponding protocol, allowing the SADP to be easily and quickly applied by the host computer.
  4. The pipette is equipped with powerful sensors and algorithms, which can be applied to all kinds of reagents for high-speed liquid level detection, shielding the interference of liquid film, while supporting the function of sample clot detection.
  5. This pipette allows for automatic disposable tips pick-ups and ejection, as well as disposable tips drop detection.
  6. Advanced cylinder processing technology, strict inspection procedures, and unique sealing solutions to ensure that the cylinder's service life can reach more than 1 million cycles without maintenance.
  7. Excellent chemical and wear resistance of the materials of the components in contact with the disposable tips, which ensures that the disposable tips cones do not require be replaced during life cycle.
  8. This pipette weighs less than 400g per pipette, making it lightweight and convenient.
Specification:
SADP18 Series CV & Precision
Single aspirate single dispense
disposable tips specification/ul Dispense volume/ul Dispense accuracy Dispense CV
50 (with filter element / cartridge filter) 5 5.0% 3.0%
50 10 3.0% 2.0%
200 (with filter element / cartridge filter) 10 6.0% 3.0%
200 50 2.0% 0.75%
1000 10 10.0% 5.0%
1. The test environment is 21-25ºC static wind environment;
2. The test mode is non-contact dispense method;
3. Replace the disposable tips with a new one after each full stroke.

Single aspirate multi-dispense
disposable tips specification/ul Dispense volume/ul Dispense accuracy Dispense CV
1000 (with filter element / cartridge filter) 20 7.5% 3.0%
1000 50 5.0% 2.0%
200 10 5.0% 3.0%
1. The test environment is 21-25ºC static wind environment;
2. The test mode is non-contact dispense method;
3. Replace the disposable tips with a new one after each full stroke.

Product photo:
Air Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics ApplicationAir Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics ApplicationAir Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics ApplicationAir Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics ApplicationAir Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics ApplicationAir Displacement Pipettor for PCR/Automated Liquid Handling System/Molecular Diagnostics Application

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
449
Year of Establishment
2010-11-16