• Single Channel Pinch Valve for Medical/Pharmaceutical/Laboratory Application
  • Single Channel Pinch Valve for Medical/Pharmaceutical/Laboratory Application

Single Channel Pinch Valve for Medical/Pharmaceutical/Laboratory Application

Size: 58*φ25mm
Transport Package: Bulk Package
Specification: CE, RoHS
Trademark: Keyto
Origin: China
Samples:
US$ 16/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Gold Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (25)

Basic Info.

Model NO.
1224-22-D1C/5N
HS Code
8481804090
Production Capacity
200, 000 PCS/Year

Product Description

1. Product Overview
The 1224 series solenoid valve is a family of single channel pinch valves. This series
solenoid valve is a high performance, low cost and maintenance free pinch valve with
multiple model options, controlling the switch of flow path for different types of tube. The
life cycle of valves can be more than 2 million. The tubing of solenoid valve is simple and
easy to clean, applying to the application that test samples are with impurities and
particulate matters and avoid cross-contamination among samples.

1.1.Characteristics Of 1224 Series
Silicon tube specification: 2mm X 4mm, shore hardness: 60;
Flow capacity: 2mmX4mm silicon tube, CV0.05, flow8.5mL/s (differential pressure
50KPa, 25ºC, pure water)
Wetted material depends on the silicon tube;
Long lifetime, high performance.
 
Response time (T)
  Input air/water at 0.25MPa and maximum working pressure drop from inlet port, input
rated control electrical signal to make the tested solenoid valve open and close, then we'll
get the change of outlet pressure which we can measure from pressure sensor. At the
same time, we'll get the lapse of time which starts from power on/off to rise to 90% of max
pressure (normally closed valve) and drop to 10% of max pressure (normally open valve)
by quick response time measure devise. Repeatedly test several times and take the
average valve as the power on response time and the power off response time.
  As engineering experience, it is the design critical value that response time above
50ms. The aspiration of valve may not stable. Therefore, the response time is not beyond
50ms within nominal lifetime.
  In addition, there is a response time at current method in this industry. The change of
circuit leads to current change, according to the action of solenoid valve. The response
time T1, T2 at current method is normally less than the response time(T) which measured
by air flow method.
 
Shut off pressure
When the normally open solenoid valve is powered on, pinch connection is suitable
for silicon tube with dimension 2.0x4.0mm, shore hardness 60. One side of tube is under
1.2 times nominal pressure water (5ºC~40ºC), and holding for one minute, the other side
should no liquid leakage.
When the normally closed solenoid valve is powered off, pinch connection is pinch
connection is suitable for silicon tube with dimension 2.0x4.0mm, shore hardness 60. One
side of tube is under 1.2 times nominal pressure water (5ºC~40ºC), and holding for one
minute, the other side should no liquid leakage.
Specification:  
Valve Type
Normally opened pinch valve (1224-1 series), Normally
closed pinch valve (1224-2 series)
Model 1224-22-D1C/5N Single Channel Pinch Valve
Interface method bottom / bracket mounting
Outline dimension 58 * Φ25 mm
Orifice diameter 2 mm
Tube specification
2mm×4mm
Recommend tube hardness Shore hardness: 60
Power consumption
12v: 5.1w, 24v: 5.4w
Withstand pressure
-70KPa~250KPa (1224-1 series), -70KPa~150KPa (1224-2
series)

Photo
Single Channel Pinch Valve for Medical/Pharmaceutical/Laboratory Application






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
449
Year of Establishment
2010-11-16